USAfixTM - Repair Guide (RG) - Master Email RG
- Check Hall Sensor
 Level of Difficulty - High  Estimated Completion Time - 10 minutes
TASKI - SWINGO XP

Tools Required
Tool 
Volt meter (True RMS capable)
Wrench-Allen metric 5.0mm

Parts Required


Step Procedure & Parts & Tools
1 REMOVE THE 3 SCREWS HOLDING THE CONTROL BOARD.
Wrench-Allen metric 5.0mm

2 PULL THE CONTROL BOARD DOWN TO EXPOSE THE WIRING. TURN THE KEY ON AND PUSH THE BRUSH BUTTON TO LOWER THE BRUSHES.

3 LOCATE THE RED AND WHITE STRIPED BRUSH PRESSURE SENSOR WIRE ON THE POWER BOARD. INSERT THE VOLT METER LEADS INTO THE PLUG.
Volt meter (True RMS capable)

4 PRESS THE BRUSH PRESSURE MINUS BUTTON ON THE CONTROL PANEL.

5 THE VOLT METER SHOULD READ APPROX. 1.9 VOLTS.
Volt meter (True RMS capable)

6 PRESS THE BRUSH BUTTON ON THE CONTROL PANEL. YOU NOW HAVE 2 LIGHTS LIT UP. THE VOLT METER SHOULD READ APPROX. 2.6 VOLTS.
Volt meter (True RMS capable)

7 PRESS THE BRUSH PRESSURE PLUS BUTTON ON THE CONTROL PANEL. YOU NOW HAVE 3 LIGHTS LIT UP. THE VOLT METER SHOULD READ APPROX. 3 VOLTS. IF THE VOLTAGE IS CORRECT, THE HALL SENSOR IS OKAY. REPLACE THE CONTROL BOARD.